• send
Rolled metal from warehouse and on order
AZOVPROMSTAL
We offer the best steel prices
+38 (098) 875-40-48
Азовпромсталь
  • Sheet steel in Mariupol, Dnipro and Kiev

    There are more than 2000 tons of sheet products in the company's warehouse. Various grades of steel, including st45, 65G, 10HSND, 09G2S, 40X, 30HGSA and foreign analogues S690QL, S355, A514, etc.
  • Steel rental on

    In the shortest possible time, we will produce any quantity of sheet steel of specified dimensions

Stationary high-voltage stand SVS-100Ts

Стенд высоковольтный стационарный СВС-100Ц

This installation is designed to check the quality and level of insulation of various protective equipment, such as rubber boots, insulation bars, gloves. But components may fail, so you need Repair of SVS 100C .

What parts can burn out

The high-voltage test bench contains elements that are subject to the risk of burnout or failure during the active operation of the device:

High voltage unit . When operating in the specified modes, the block components can simply wear out, which will render it inoperative.

Short-circuiter . When a short circuit is created, which should go to ground, the voltage can go to the device itself.

High voltage diode . A semiconductor element with large regular loads can easily burn out.

Current limiting resistor . When a lower voltage is applied to the elements of the stand, an increase in power in the resistor itself may occur.

Control unit . Physical deterioration of the controls or a short circuit can damage the device.

The rest of the stand elements are also susceptible to failure.

Rules of operation and storage

Timely response to inadequate operation of the high-voltage test bench and regular technical inspection at the service center will help extend the life of the device:

  • wipe the contact surfaces with an alcohol solution twice a month;
  • weekly inspect the tightness of the closure on the contact surfaces;
  • check the grounding every time the device is in operation;
  • avoid condensation on connectors and live parts;
  • if the stand is not used for a long time, it must be carefully preserved;
  • when transporting the stand, ensure that it is securely fixed.

If the installation malfunctions, then you should not postpone the inspection and give it to trusted specialists for service. They will help to identify whether it was an accidental malfunction, or the stand was used in the wrong production conditions. Insufficient awareness of personnel about working with this equipment can also lead to repairs.



Азовпромсталь